Site Maintenance

Keep the measurement site in good order to ensure reliable
measurements:
- Check that the vegetation surrounding the station does not get too

long/close to equipment. Regular clipping is advised.

- Check that snow does not touch or cover the enclosure and

connectors.

- Avoid disturbing the possible snow cover under the Snow Depth

Sensor IRU-2429 to have representative measurement.

Mast DKP210 Maintenance

Periodic Maintenance

Check the mast yearly for any damage to the coating. Inspect the guy
wires for correct tightness yearly as well. When checking the mast,
perform at least the following maintenance tasks:
- Check the guy wires from fraying.
- Check the guy wire clamps and tighten when necessary.
- Check the sensor support and tighten when necessary.
- Check the hinge bolts and tighten when necessary.

When devices installed on the upper assembly need maintenance, you
need to tilt the mast. See section Tilting Mast below.

Tilting Mast

You need to tilt the mast when, for example, devices installed on the
upper assembly need maintenance. The maintenance of the following
sensors and accessories should be carried out when the mast is tilted:

- Ultrasonic

Wind

Sensor

WMT703, as described in section Ultrasonic

Wind Sensor WMT703 Maintenance on page 176

- Mechanical Wind Sensor Set WA15, as described in section

Mechanical Wind Sensor Set WA15 Maintenance on page 186

- Solar Panel SOLAR33, as described in section Solar Panel SOLAR33

Maintenance on page 179

- GSM/GPRS antenna, as described in section GSM/GPRS Antenna on

page 175

The following sections provide instructions on tilting the mast.