TECHNICAL REFERENCE___________________________________________________________
26 __________________________________________________________________ M211097EN-C
wires must be properly isolated and terminated to avoid unwanted
operation or failure.
Table 4
ROSA Cable 10m (231425SP)
Power Supply
Wire Colors Pin
Operating Power Supply
White
1
Operating Power Supply Ground
Gray-Pink
11
Heater Power Supply
Gray
5
Heater Power Supply
Pink
6
Heater Power Supply Ground
Blue
7
Heater Power Supply Ground
Red
8
Enclosure Ground
Shield
Shield
Analog Outputs
Analog Output AOUT2, Wind Direction
Brown
2
Analog Output AOUT1, Wind Speed
White-Green 13
Reference Input for AOUT2 (simulated potentiometer)
White-Gray
17
Analog Output Ground
Red-Blue
12
COM port
RS-232
RS-485
RS232Rx RxB
Green
3
RS232Tx TxB
Yellow
4
- TxA
Brown-Green
14
COM2
- RxA
White-Yellow
15
COM1 and COM2 Communication Ports Ground
Violet
10
RS-485, B
Black
9
COM1
(service port) RS-485, A
Brown-Yellow 16
Other WMT700 Standard Cables
For instructions on connecting WMT700 to the host device for other
operation modes or using the WMT700 cable, see Vaisala WINDCAP
®
Ultrasonic Wind Sensor Series WMT700 User's Guide.
Using WS425 Cables with adapters
If retrofit installation using WMT700 cables is not possible, there are
adapters available for most of the situations.
- Adapter Cable for WS425 Serial (227569SP)
- Adapter Cable for WS425 Analog Frequency Output (227570SP)
- Adapter Cable for WS425 Analog Voltage Output (227571SP)
The adapter cable specifications in this section apply for both heated and
non-heated versions of WMT700.