Other wmt700 standard cables, Using ws425 cables with adapters – Vaisala WMT700 User Manual

Page 28

Advertising
background image

TECHNICAL REFERENCE___________________________________________________________

26 __________________________________________________________________ M211097EN-C

wires must be properly isolated and terminated to avoid unwanted
operation or failure.

Table 4

ROSA Cable 10m (231425SP)

Power Supply

Wire Colors Pin

Operating Power Supply

White

1

Operating Power Supply Ground

Gray-Pink

11

Heater Power Supply

Gray

5

Heater Power Supply

Pink

6

Heater Power Supply Ground

Blue

7

Heater Power Supply Ground

Red

8

Enclosure Ground

Shield

Shield

Analog Outputs

Analog Output AOUT2, Wind Direction

Brown

2

Analog Output AOUT1, Wind Speed

White-Green 13

Reference Input for AOUT2 (simulated potentiometer)

White-Gray

17

Analog Output Ground

Red-Blue

12

COM port

RS-232

RS-485

RS232Rx RxB

Green

3

RS232Tx TxB

Yellow

4

- TxA

Brown-Green

14

COM2

- RxA

White-Yellow

15

COM1 and COM2 Communication Ports Ground

Violet

10

RS-485, B

Black

9

COM1
(service port) RS-485, A

Brown-Yellow 16

Other WMT700 Standard Cables

For instructions on connecting WMT700 to the host device for other
operation modes or using the WMT700 cable, see Vaisala WINDCAP

®

Ultrasonic Wind Sensor Series WMT700 User's Guide.

Using WS425 Cables with adapters

If retrofit installation using WMT700 cables is not possible, there are
adapters available for most of the situations.

- Adapter Cable for WS425 Serial (227569SP)
- Adapter Cable for WS425 Analog Frequency Output (227570SP)
- Adapter Cable for WS425 Analog Voltage Output (227571SP)

The adapter cable specifications in this section apply for both heated and
non-heated versions of WMT700.

Advertising