Chapter 5 ______________________________ Operating WMT700 with WS425 and SDI-12 profiles

VAISALA _______________________________________________________________________ 43

For the correct settings for SDI-12 profile, see section SDI-12 on
page 60.

7. Click

Apply and OK.

8. On

the

Settings tab, click ASCII setup. Select ASCII sending -

Send line ends with line feed (optional). Click OK and close the
New Connection Properties window.

9. On

the

View menu, click Font. In the Font list, select Terminal.

10. From

the

Call menu, click Call. Enter a name and select an icon

for the connection. Click OK.

11. Switch the sensor power supply on.

The following information is displayed:

wmt700 v.<version number>

12. Wait for 4 seconds. WMT700 enters measurement mode

automatically.

13. To test the connection, enter configuration mode with the following

command.


$0OPEN<CR><LF>

14. Use the following command to return to measurement mode:

CLOSE<CR><LF>

You can now start operating WMT700. However, WMT700 does
not send data messages automatically unless configured to do so.

For information on operating commands and data messages, see the
profile-specific section in Vaisala WINDCAP

®

Ultrasonic Wind

Sensor Series WMT700 User's Guide.