Ws425 a/b ascii profile, Configurable parameters – Vaisala WMT700 User Manual

Page 57

Advertising
background image

Chapter 5 ______________________________ Operating WMT700 with WS425 and SDI-12 profiles

VAISALA _______________________________________________________________________ 55

WS425 A/B ASCII Profile

NOTE

In Vaisala WINDCAP

®

Ultrasonic Wind Sensor WS425 User's Guide,

this profile was called the Handar mode.

Configurable Parameters

Table 17 below lists the configurable parameters and their allowed and
default values for the WS425 A/B ASCII Profile.

Table 17

Configurable Parameters for WS425 A/B ASCII
Profile

Parameter Default

Value

Profile-specific
Allowed Values

Description

autoInt

1

0.25 ... 1000
Resolution: 0.25

Automatic message interval in seconds.
Do not select a message interval that is shorter
than the time it takes to send a data message.

autoPort 1 1=COM1

port

2=COM2 port

Serial port to which WMT700 sends automatic
data messages.

autoSend

0

0 = automatic
messages disabled

Automatic data message number. Selects the
data message format for automatic messages.

com1_protocol
com2_protocol
(depending on
the port used for
operating
WMT700)

0

3 = WS425 A/B
ASCII

Profile for serial ports COM1 and COM2.

wndOrientation

0

0 = array facing up
1 = array facing
down

Orientation of the array of WMT700.

wndUnit

0

0 = meters per
second
1 = miles per hour
2 = kilometers per
hour
3 = knots

Wind speed unit.

wndVector

1

0 = scalar averaging

Wind averaging method.

To start continuous measurement, use the START command. You can
stop the measurement with the STOP command. For instructions, refer to
Vaisala WINDCAP

®

Ultrasonic Wind Sensor Series WMT700 User's

Guide.