TECHNICAL REFERENCE___________________________________________________________

30 __________________________________________________________________ M211097EN-C

Table 8

Analog Output Connections

WMT700
Connector
Pin

WMT700 Signal
Description

Voltage Output WS425 Connector Pin,

Wire Color

Voltage

15: Violet (connect pin 14
to ground)

Current not

available

13 Analog

Output

AOUT1, Wind
Speed

Frequency 14,

Pink

Voltage 13,

Grey

Current not

available

2 Analog

Output

AOUT2, Wind
Direction

Potentiometer 13,

Grey

17 Reference

Input

for AOUT2

Potentiometer 12,

White

12 Analog

Output

Ground

All modes

1, Black (common with
supply ground)

Powering

WMT700 is designed to operate with the same supply voltages as WS425
and no connection changes are necessary. The power consumption
depends on the selected heating options. WMT700 with Heated
Transducers can be used to replace similar WS425 models. When
upgrading from WS425 to WMT700 with Heated Transducers and Arms,
more capacity is required from the power supply unit.

For information on power supply requirements of each WMT700 product
type, see Table 9 below.

For more information on powering, see Vaisala WINDCAP

®

Ultrasonic

Wind Sensor Series WMT700 User's Guide.

Table 9

Heating Power Supply Requirements for WMT700
Series

Heating Option

Heating Voltage

Required Heating
Power Supply

None -

-

Transducers

24/36 VDC

40 W

Transducers and arms

24 VDC

200 W