These settings are factory preset, and should never be changed. If they

have been changed, they must be changed back to the following, or the
Pan and Tilt motors can be damaged.



KP: 80 KI:15
KD:250 IL: 25

After the setting is made, move the cursor box to the “ok” option, and press “enter”. The
settings will not be saved until this is done.
Settings should be the same for both pan and tilt axes.

15. System resets

The “reset all” option is found in the second setup menu screen.
When selected this will reset all parameters only. All stored marks, and takes will not be
effected.

To reset all motor parameters only, turn the console power off
Hold the “cancel” and “stop” button simultaneously. While holding both buttons turn
console power on.
The screen will then read “Accept = reset all motors”
Press the “enter” button, and all motor parameters will be reset.

To erase all takes turn console power off.
Hold the “cancel” and “record” buttons simultaneously. While holding both buttons turn
console power on.
The screen will then read “Accept = erase all takes”
Press the “enter” button, and all takes will be erased.

To erase all marks turn console power off.
Hold the “cancel” and “play” buttons simultaneously. While holding both buttons turn
console power on.
The screen will then read “Accept = erase all marks”
Press the “enter” button, and all marks will be erased
Note: resetting all motor parameters is recommended after updating system software. It
is also recommended if the systems memory ends up corrupted.