VariZoom VZCINEMAPRO-K2 User Manual
Page 25
- 24 -
1
Camera Neg.
Black
2
Cinema Pro Neg.
White
3
Cinema Pro Pos.
Red
4
Camera Pos.
Green
2) Camera Power Connector
Pin
Function
Destination
1
Camera Neg.
Loop to Power Connector
2
N.C.
3
N.C.
4
Camera Pos.
Loop to Power Connector
*** WARNING: DO NOT POWER THE CINEMAPRO WITH ANYTHING OTHER
THAN THE INCLUDED FACTORY POWER SUPPLY OR YOUR WARRANTY MAY BE
VOIDED. THE UNIT MAY BE SEVERELY DAMAGED AND CAUSE DAMAGE TO
YOUR CAMERA IF YOU USE A NON-APPROVED POWER SUPPLY. IF YOU MUST
POWER IT USING A BATTERY SYSTEM, MAKE SURE THE SETUP IS APPROVED
BY VARIZOOM AND EXECUTED BY A QUALIFIED TECHNICIAN.
Cinema Pro Head - Base Connectors
1) Control Connector (green) – LEMO EGG1B307CLL
Pin
Function
Wire Color (Cable)
1
Common
Brown
2
RS-422 RXD
Red
3
RS-422 RXD!
Orange
4
RS-422 TXD
Yellow
5
RS-422 TXD!
Green
6
24 VDC +
Blue
Power to Remote or Jibstick
7
24 VDC -
Violet
Power to Remote or Jibstick
2) Kuper Node Connector (red) – LEMO EGG1B306CLL
Pin
Function
DB9
1
Common
1
2
N.C.
3
RS-422 RXD (Kuper)
8
4
RS-422 RXD! (Kuper)
9
5
RS-422 TXD (Kuper)
5
6
RS-422 TXD! (Kuper)
6