Agency listings and approvals, Product line information – Notifier 8100(A) User Manual

Page 2

Advertising
background image

Page 2 of 2 — DN-60791:A • 10/1/13

NOTIFIER®, FlashScan®, PipeIQ®, and FAAST Fire Alarm Aspiration

Sensing Technology® are registered trademarks of and Acclimate™is a

trademark of Honeywell International Inc.

©2013 by Honeywell International Inc. All rights reserved. Unauthorized use

of this document is strictly prohibited.

This document is not intended to be used for installation purposes.

We try to keep our product information up-to-date and accurate.

We cannot cover all specific applications or anticipate all requirements.

All specifications are subject to change without notice.

For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.

www.notifier.com

Made in the U.S. A.

PHYSICAL SPECIFICATIONS

Height: 13.25 inches (33.7 cm).
Width: 13.0 inches (33 cm).
Depth: 5.0 inches (12.7 cm).
SLC Connection: Standard SLC connections. Class B (for-

merly Style 4) or Class A (formerly Style 6/7).
Relays: 8 Form C, 3 AMP, programmable latching or non-

latching.
Communication Network: Ethernet monitoring, 6 E-mail

address alerts, Modbus/TCP.
Cable Access: 4 1-inch (2.54 cm) cable entry holes on top

and bottom of unit.
Wire Gauge: 12 AWG (2.05 mm) max. to 24 AWG (0.5 mm)

min.
Maximum Single Pipe Length: 262 ft. (80 m).
Maximum Branched (2) Pipe Length: 165 ft. (50 m) each

branch.
Maximum Air Inlet Holes: 40 holes.
Network Outside Pipe Diameter: 1.050 inches, IPS (25 mm).
Internal Pipe Diameter: 0.591 to 0.827 inches (15-21 mm).
Sensitivity Range: 0.00046%/ft. obs – 4.0%/ft. obs.
Event Log: 18,000 events stored.
Shipping Weight: 11.6 lbs. (5.26 kg), includes packing mate-

rial.
User Interface Display:
• Five alarm levels (Alert, Action 1, Action 2, Fire 1, and

Fire 2).

• Ten particulate levels.

• Ten bi-color flow.
• Fault graph.

Agency Listings and Approvals

The listings and approvals below apply to Intelligent FAAST

Series components. In some cases, certain modules or applica-

tions may not be listed by certain approval agencies, or listing

may be in process. Consult factory for latest listing status.

UL Listed: S911.

ULC Listed: S911.

FM approved.

Maryland State Fire Marshal: Permit # 2244.

Product Line Information

8100 Intelligent FAAST: Conventional aspirating smoke

detector. For Canadian applications, order 8100A.
F-A3384-000: Replacement Air Filter.
F-LCARD-SP: Language Card - Spanish.
P-PIPE-210: CPVC Pipe (210 feet total).
P-COUPLING: Coupling (15 each).
P-ELB-45: 45° Elbow (10 each).
P-ELB-90: 90° Elbow (20 each).
P-ENDCAP: End Cap (25 each).
P-TEE: Tee (15 each).
P-UNION: Union (10 each).
P-LABEL-P: Pipe Label (100 each).
P-LABEL-T: Sampling Point Labels (100 each).
P-SAMP-KT: Sampling Point Kit (10 sets).
HP300ULX: Power Supply, 12/24VDC, 2.4 A DC.

User Interface Display