PROGRAMMING AND SOFTWARE:

• Custom English labels (per point) may be manually entered

or selected from an internal library file.

• Programmable Abort operation.
• Three programmable Form-C relay outputs.
• Pre-programmed and custom application templates.
• Continuous fire protection during online programming at the

front panel.

• Program Check automatically catches common errors not

linked to any zone or input point.

USER INTERFACE:

• Integral 80-character LCD display with backlighting.
• Real-time clock/calendar with automatic daylight savings

adjustments.

• ANN-Bus for connection to annunciators.
• Audible or silent walk test capabilities.
• Piezo sounder for alarm, trouble, and supervisory.

Controls and Indicators

LED INDICATORS

• FIRE ALARM (red).
• SUPERVISORY (yellow).
• TROUBLE (yellow).
• AC POWER (green).
• ALARM SILENCED (yellow).
• DISCHARGED (red).
• PRE-DISCHARGE (red indicator).
• ABORT (yellow indicator).

CONTROL BUTTONS

• ACKNOWLEDGE.
• ALARM SILENCE.
• SYSTEM RESET (lamp test).
• DRILL.
AC Power – TB1

RP-2002C: 120 VAC, 60 Hz, 3.66 amps.

Wire size: minimum #14 AWG (2.0 mm

2

) with 600V insula-

tion.

• Supervised, nonpower-limited.
Battery (sealed lead acid only) – J12:

Maximum Charging Circuit - Normal Flat Charge: 27.6

VDC @ 1.4 amp. Supervised, nonpower-limited.

Maximum Charger Capacity: 18 Amp Hour battery (two

18 Amp Hour batteries can be housed in the FACP cabinet.

Larger batteries require separate battery box such as the

BB-26 or NFS-LBBR).

Minimum Battery Size: 12 Amp Hour.

Initiating Device Circuits - TB4 and TB6
• Zones 1 - 5 on TB4.
• Zone 6 on TB6.
• Supervised and power-limited circuitry.
• Style B (Class B) wiring with Style D (Class A) option.
• Normal Operating Voltage: Nominal 20 VDC.
• Alarm Current: 15 mA minimum.
• Short Circuit Current: 40 mA max.
• Maximum Loop Resistance: 100 Ohms.
• End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 71252).
• Standby Current: 4 mA.

Refer to the Notifier Device Compatibility Document for listed

compatible devices.
Notification Appliance and Releasing Circuit(s) - TB5 and

TB7
• Four Output Circuits.
• Style Y (Class B) or Style Z (Class A) with optional con-

verter module.

• Special Application power.
• Supervised and power-limited circuitry.
• Normal Operating Voltage: Nominal 24 VDC.
• Maximum Signaling Current: 7.0 amps (3.0 amps maximum

per NAC).

• End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 71252).
• Max. Wiring Voltage Drop: 2 VDC.
Refer to the Notifier Device Compatibility Document for com-

patible listed devices.
Form-C Relays - Programmable - TB8
• Relay 1 (factory default programmed as Alarm Relay)
• Relay 2 (factory default programmed as fail-safe Trouble

Relay)

• Relay 3 (factory default programmed as Supervisory Relay)
• Relay Contact Ratings:

2 amps @ 30 VDC (resistive)
0.5 amps @ 30 VAC (resistive)

Auxiliary Trouble Input – J6
The Auxiliary Trouble Input is an open collector circuit which

can be used to monitor external devices for trouble conditions.

It can be connected to the trouble bus of a peripheral, such as

a power supply, which is compatible with open collector cir-

cuits.
Special Application Resettable Power - TB9

Operating Voltage: Nominal 24 VDC.

Maximum Available Current: 500 mA - appropriate for

powering 4-wire smoke detectors (see note).

• Power-limited Circuitry.
Refer to the Notifier Device Compatibility Document for com-

patible listed devices.

NOTE: Total current for resettable power, nonresettable power and
Output Circuits must not exceed 7.0 amps.

Special Application Resettable or Nonresettable Power -

TB9

Operating Voltage: Nominal 24 VDC.

Maximum Available Current: 500 mA (see note 1).

• Power-limited Circuitry.
• Jumper selectable by JP31 for resettable or nonresettable

power.

Refer to the Notifier Device Compatibility Document for com-

patible listed devices.