General specification, Display details – Notifier Lumidor Minimax XP User Manual

Page 3

Advertising
background image

General specification

Standard Specification

Alarm Set Points

Gases Detected

Range

Level 1

Level 2

STEL

TWA

Oxygen (O

2

)

0 to 30% v/v

23.5% v/v

19.5% v/v

n/a

n/a

Carbon Monoxide (CO)

0 to 999 ppm

35 ppm

100 ppm

400 ppm

35 ppm

Hydrogen Sulphide (H

2

S)

0 to 250 ppm

10 ppm

15 ppm

15 ppm

10 ppm

Sulphur Dioxide (SO

2

)

0 to 150 ppm

2 ppm

5 ppm

5 ppm

2 ppm

Chlorine (Cl

2

)

0 to 50 ppm

0.5 ppm

1 ppm

1 ppm

0.5 ppm

Hydrogen Cyanide (HCN)

0 to 100 ppm

5 ppm

10 ppm

10 ppm

5 ppm

Nitrogen Dioxide (NO

2

)

0 to 150 ppm

3 ppm

5 ppm

5 ppm

3 ppm

Ammonia (NH

3

)

0 to 100 ppm

25 ppm

50 ppm

35 ppm

25 ppm

Hydrogen (H

2

)

0 to 999 ppm

100 ppm

500 ppm

n/a

n/a

Construction

General

Serviceable, portable single gas monitor for personal protection against Oxygen and toxic gas hazards

Calibration

Time between calibrations is maximized utilizing cell decay compensation facility.

The maximum time between calibrations is 12 months

#

Operating Life

Sensor (replaceable) Minimum of 2 years

Battery (replaceable) 3 years*

Operating Temperature

-20°C to +50°C (-4°F to +122°F) (temperature compensated)

Humidity 5-95%

RH

(non-condensing)

Audible Alarm

95dB @ 10cm (3.9")

Visual Alarm

High intensity Red LEDs

Vibrating Alarm Standard

Display

Ultra clear backlit LCD displays gas levels & instrument status

Sensor Type Electrochemical

(replaceable)

Battery Type

Lithium CR2, 3.0v (replaceable)

Diagnostics

Self-test of circuitry, battery, LCD, and software. Sensor test using patented Reflex

sensor technology

Environmental

IP Rating IP54

(minimum)

Intrinsic Safety

North America: Class 1, Div 1, Groups A, B, C, D, T4 (UL/cUL)

Europe: II 2G EEx ia IIC T4 (ATEX)

RFI/EMC

CE EN50270:1999 and EN55011

Dimensions

93mm (H) x 50mm (W) x 27mm(D)

(3.6" x 2" x 1.1") excluding clip

Weight

Toxic

81.5g (2.8oz)

Oxygen

93.0g (3.3oz)

*Operating Life may be reduced by excessive alarms

Reflex not available on all sensors

#

H

2

S/CO only

Display Details

A

C

B

I

F

G

D

H

E

J

A

Battery

Fail

Self-test pass icon

Level 1: O

2

and toxics

Level 2: Toxics

Level 2: O

2

STEL/TWA alarm

Cal. Status icon

Low peak (O

2

), High peak

(O

2

and toxics)

Gas concentration and units

Alarm icon

B

C

D

E

F

G

H

I

J

* Oxygen detection products must only be
used to detect oxygen depletion in air.

Advertising