2 power supply connection 24vac, 3 power supply connection 120/230vac, 4 video cable connection – Videotec ULISSE User Manual

Page 21: 1 telemetry line connections

Advertising
background image

EN - English - I

nstruc

tions manual

19

7.2.4 Video cable connection

h

The installation is type CDS (Cable
Distribution System), do not connect it to
SELV circuits.

h

In order to reduce the risk of fire, only use
cable sizes greater than or equal to 26AWG.

h

Connect the screen and central cable
respectively to the GND and VIDEO
terminals. The terminals accept cables
with sections between 0.5 mm2 (AWG20)
and 0.08 mm2 (AWG28).

GND

VIDEO

Signal

Fig. 30

7.2.4.1 Telemetry line connections

h

The installation is type TNV-1, do not
connect it to SELV circuits.

h

In order to reduce the risk of fire, only use
cable sizes greater than or equal to 26AWG.

The product is supplied with 2 RS485 serial
communication lines and 1 RS232 serial line. These
can be configured in various ways according to the
positions of dip-switches 10 and 9 on the Serial and
Address
selector ("7.4.5 Serial communication lines",
page 22
).

A1

B1

A2

B2

Signal

Fig. 31

TERMINALS

DESCRIPTION

A1-B1

Line RS485 (1)

A2-B2

Line RS485 (2)

Tab. 06

7.2.3.2 Power supply connection 24Vac

Connect the power supply cables as described in the
table below.

POWER SUPPLY CONNECTION 24VAC

Colour

Terminals

Defined by the installer

(N) Neutral

Defined by the installer

(L) Phase

Yellow/Green

Earth

Tab. 04

h

Only for products marked UL intended for
the North American market, use a class 2 UL
listed transformer.

7.2.3.3 Power supply connection
120/230Vac

Connect the power supply cables as described in the
table below.

POWER SUPPLY CONNECTION 120/230VAC

Colour

Terminals

Blue

(N) Neutral

Brown

(L) Phase

Yellow/Green

Earth

Tab. 05

h

Use the appropriate junction-box
UPTJBUL t
o connect the power supply
line. For further information, refer to the
product use and installation manual.

Advertising