7.4.4 Setting the address

The ULISSE address can have a setting from 1 to 255.
Binary code is used to select the address, using the
8 dip-switches at the top right ("17 Appendix A - Dip-
switch address table", page 63
).

7.4.5 Serial communication lines

The product is designed with two RS485 serial
communication lines and one RS232 serial line, which
can have various settings according to the positions
of dip-switches 10 and 9 on the Serial and Address
selector.

j

When the dip-switch rocker is up it
represents the value 1 (ON) while if it is
down it represents the value 0 (OFF).

SERIAL AND ADDRESS, SERIAL LINE CONFIGURATION

DIP

10

DIP

9

DIP

8-1

Configuration

OFF OFF

-

It allows the one-way communication

on RS485-1 line ("7.4.5.1 RS485 RX line",

page 23).

OFF ON

-

It allows the full-duplex communication

according to RS422 standard ("7.4.5.2

RS422 line (RS485-1 RX and RS485-2 TX)",

page 23).

ON OFF

-

It allows the cascade configuration of

different devices. The signal is repeated

from every units ("7.4.5.3 RS485-1

line reception, RS485-2 line repetition",

page 23).

ON

ON

-

It allows the two-ways, half-duplex,

communication on RS485-1 line ("7.4.5.4

RS485 TX/RX line", page 23).

Tab. 10

7.4.2 Setting the baud rate

Dip-switches 4, 3 and 2 are used to set the
communication rate of the device according to the
table below.
Dip-switch number 1 is used to update the firmware.
During normal use, make sure the rocker is OFF
(DIP1=OFF).

j

When the dip-switch rocker is up it
represents the value 1 (ON) while if it is
down it represents the value 0 (OFF).

BAUDRATE SETTING

Description

DIP

4

DIP

3

DIP

2

DIP

1

Configuration

Baudrate

adjustment

OFF OFF OFF

-

300 baud

ON OFF OFF

-

600 baud

OFF ON OFF

-

1200 baud

ON

ON OFF

-

2400 baud

OFF OFF ON

-

4800 baud

ON OFF ON

-

9600 baud

OFF ON

ON

-

19200 baud

ON

ON

ON

-

38400 baud

Firmware update

-

-

-

ON

Set up enabled

-

-

-

OFF

Set up disabled

Tab. 08

7.4.3 Setting the protocol

Video positioning systems with the ULISSE line can be
controlled by a range of protocols.

j

When the dip-switch rocker is up it
represents the value 1 (ON) while if it is
down it represents the value 0 (OFF).

PROTOCOL SETTING

DIP

8

DIP

7

DIP

6

DIP

5

DIP

4

DIP

3

DIP

2

DIP

1

MACRO

(VIDEOTEC)

OFF OFF OFF OFF OFF ON ON ON

PANASONIC

OFF OFF OFF ON OFF ON OFF OFF

PELCO D

OFF OFF OFF OFF ON OFF OFF ON

AMERICAN
DYNAMICS

OFF OFF OFF OFF ON ON ON OFF

VISTA

OFF OFF OFF ON OFF OFF ON ON

Tab. 09