SERIAL LINE CONNECTION

Description

SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Configuration

Address

OFF

OFF

OFF

OFF

OFF

–

–

–

Reserved

Address

ON

OFF

OFF

OFF

OFF

–

–

–

Address 01

Address

OFF

ON

OFF

OFF

OFF

–

–

–

Address 02

Address

ON

ON

OFF

OFF

OFF

–

–

–

Address 03

…

…

…

…

…

…

–

–

–

…

Address

ON

ON

ON

ON

ON

–

–

–

Address 31

Baud rate

–

–

–

–

–

ON

–

–

9600baud (PELCO D),

38400baud (VIDEOTEC MACRO)

Baud rate

–

–

–

–

–

OFF

–

–

2400baud (PELCO D),

9600baud (VIDEOTEC MACRO)

Protocol

–

–

–

–

–

–

ON

–

PELCO D

Protocol

–

–

–

–

–

–

OFF

–

VIDEOTEC MACRO

Pre-installed module

–

–

–

–

–

–

–

ON

SONY

Pre-installed module

–

–

–

–

–

–

–

OFF

FLIR

Tab. 9

7.3.11 Special controls

SPECIAL CONTROLS

Control

Protocol

PELCO D

VIDEOTEC MACRO

Wiper Start

Save Preset 85

Save Preset 85

Aux 3 ON

Aux 3 ON

Wip+

Wiper Stop

Save Preset 86

Save Preset 86

Aux 3 OFF

Aux 3 OFF

Wip-

Washer Start

Save Preset 87

Save Preset 87

Aux 4 ON

Aux 4 ON

Was+

Washer Stop

Save Preset 97

Save Preset 97

Aux 4 OFF

Aux 4 OFF

Was-

Night Mode on

Save Preset 88

Save Preset 88

Aux 2 ON

Aux 2 ON

Aux+

Night Mode off

Save Preset 89

Save Preset 89

Aux 2 OFF

Aux 2 OFF

Aux-

Reboot

Save Preset 94

Save Preset 94

Tab. 10

Advertising
This manual is related to the following products: