1 atex-iecex certificate details, 1 temperature, 2 installation instructions – Videotec MAXIMUS MHXT User Manual

Page 9: 3 mounting instructions

Advertising
background image

Instruc

tions manual - English - EN

9

3.1 ATEX-IECEX certificate details

3.1.1 Temperature:

The relation between ambient temperature range, gas group and Ex code is as follows:

Environment temperature

Gas group

EX marking

-40°C to +60°C

IIB

II 2 G Ex d IIB T6 Gb Ta -40°C to +60°C

-20°C to +60°C

IIC

II 2 G Ex d IIC T6 Gb Ta -20°C to +60°C

-40°C to +60°C

IIC

II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C

Tab. 1

3.1.2 Installation instructions

All cable connectors/glands shall be ATEX/IECEx certified, as appropriate, in type of explosion protection “d”

and/or "tb", rated IP66/67, suitable for the conditions of use and correctly installed.
When conduit is used, a suitable ATEX/IECEx certified stopping box shall be used, as appropriate, in type of

explosion protection “d” and/or "tb", rated IP66/67, suitable for the conditions of use and correctly installed. The

stopping box must be fitted within 25mm (1in) from the enclosure wall.
Unused cable entries are to be closed off using closing devices ATEX/IECEx certified, as appropriate, in type of

explosion protectio n “d” and/or "tb", rated IP66/67, suitable for the conditions of use and correctly installed.
For ambient temperatures below –10°C use field wiring suitable for minimum ambient temperature.
Cable entries and field wiring must be suitable for an operating temperature of at least +30°C above ambient.

3.1.3 Mounting instructions

The MHX and MHXT series CCTV camera housings can be mounted at any angle between ±90° from horizontal.