3 electrical rating, 4 cable glands, 3 electrical rating 13.4 cable glands – Videotec MAXIMUS MHXT User Manual

Page 41

Advertising
background image

Instruc

tions manual - English - EN

41

13.3 Electrical rating

ELECTRICAL RATING

Power supply

Max peak electrical ratings (comprising

the max power dissipation of the end

user camera/lens and heater)

Maximum power dissipation for end

user fitted camera/lens

230Vac

0.34A, 50/60Hz, 80W

13W

120Vac

0.5A, 50/60Hz, 60W

13W

24Vac

2.2A, 50/60Hz, 53W

13W

12Vdc

2.8A, 34W

13W

Tab. 12

13.4 Cable glands

3/4" NPT CABLE GLAND SELECTION LAYOUT

Zone, Gas

Cable gland

type

Certification Operating

temperature

Cable

Cable glands

part code

Diameter of

the external

cable (mm)

Under armor

cable diame-

ter (mm)

IIC, Zone 1 or

Zone 2

IIB or IIA,

Zone 1

Barrier

IECEX/ATEX/

GOST

-60 / +80°C

(-76°F /

+176°F)

Not armored

OCTEXB3/4C

13 - 20.2

Armored

OCTEXBA3/4C 16.9 - 26

IIB or IIA,

Zone 2

With gasket

IECEX/ATEX/

GOST

-60 / +100°C

(-76°F /

+212°F)

Not armored

OCTEX3/4C

13 - 20.2

Armored

OCTEXA3/4C

16.9 - 26

11.1 - 19.7

ATEX

-20 / +80°C

(-4°F / + 176°F)

Not armored

OCTEX3/4

14 - 17

Armored

OCTEXA3/4

18 - 23

14 - 17

Tab. 13