MagTek IntelliCAT99875658 User Manual

Page 13

Advertising
background image

<IntelliCAT>| <Migration to Windows 7> | <User Support Document>

Page 13

Win 7 64BIT and SQL

Action Required

If a Controller.UDL is present and using SQL

Make one change. For (Win 7 64bit only),

Note: If a SQL database is being used in XP 2.XX and
you are migrating to a Win 7 64bit environment, a
Controller. UDL is not required but one may be in use.
If in use, follow this step.

Complete

Step 12 B

as referenced above (create a

new Controller64.UDL and change the connection
string to reflect Program Files (x86) in the path
structure and change the [ODBC] WorkQConnect
string to reflect Controller64.UDL

Both the Controller.UDL and the Controller64.UDL will
be utilized during the PC migration

Step 18

- Import Operators into new Network folder(s)

Import Operators, using ICAT utility into the appropriate database examples in

S

tep 15

above using

14

A

if an operator’s folder is not utilized or use

14

B

if an operator folder is in use.

15

A

- Use the networked MtAdmin.MDB located in \\server1\MagTek\IntelliCAT\ to import

the Operators into \\server1\MagTek\2.X_IntelliCAT\ via the newly created IntelliCAT.UDL

or IntelliCAT64.UDL path referenced in the [ODBC] section.

15

B

- Use the networked MtAdmin.MDB located in \\server1\MagTek\IntelliCAT\Operators\

to import the Operators into \\server1\MagTek\2.X_Operators\ via the newly created

Operator.UDL or Operator64.UDL path referenced in the [ODBC] section.

Step 19

- Win 7, 64bit only – Mandatory Step

If Controller is being used, under the [Controller] section on the Desktop INTCAT.INI file

CHANGE

the

WorkLocation from:

WorkLocation="C:\Program Files (x86)\MagTek\IntelliCAT\" to

WorkLocation="C:\MagTekWork\"

then

NAVIGATE

to C:\ and create a subfolder called MagTekWork.

Set the permissions to this folder as noted in

S

tep 21.

Step 20

- File and Save INTCAT.INI to C:\Windows

If the INTCAT.INI file is open and the customization has been completed, click, file,

SAVE

and

CLOSE

.

Then take a copy of the desktop INTCAT.INI file and

COPY

and

PASTE

it to C:\Windows.

Overwrite the existing INTCAT.INI.

Step 21

- Set Permissions

1.

NAVIGATE

to C:\Program Files or Program Files (x86)\MagTek.

RIGHT CLICK

on the MagTek

folder and go to Properties, Security.

CREATE

a MagTek User group or use Domain Users and

give full control to this folder and its child objects.

2. If networked folders are in use as well,

GO TO

the

i.e

\\server1\MagTek\

folder,

RIGHT

CLICK

Properties, Security and give full permissions to this folder and its child objects

using the

same MagTek User group or Domain Users.

3.

NAVIGATE

to C:\Windows – locate INTCAT.INI,

RIGHT CLICK

and go to Properties, Security

and

grant read (minimum) and write permissions to this file using the same group.

4. In Win 7, 64

bit,

NAVIGATE

to C:\MagTekWork,

RIGHT CLICK

and go to Properties, Security

and give full control to this folder using the MagTek User group or Domain Users group. The

same permissions apply as in #1 above.

Important Note: User Switching is not recommended, especially if Controller is used.

Step 22

- Create shortcuts

NAVIGATE

to C:\Program Files or C:\Program Files (x86)\MagTek\IntelliCAT\

Select each Executable that should be on the Desktop.

Create the appropriate shortcuts,

Highlight all, then click on

CUT

, then

NAVIGATE

to C:\Users\Public\Desktop

And

PASTE

the shortcuts to the desktop.

Advertising