MagTek IntelliCAT99875658 User Manual

Page 8

Advertising
background image

<IntelliCAT>| <Migration to Windows 7> | <User Support Document>

Page 8

12 B

- Migrating from XP 1.XX to 2.XX (Win 7, 64bit)

Create an IntelliCAT64.UDL, Operator64.UDL (Optional) and a Controller64.UDL (Optional)
XP 1.XX to 2.XX (Win 7, 64 bit) - Create a local IntelliCAT64.UDL, a local Operator64.UDL (if present
in old PC setup) and a local Controller64.UDL (if using Controller) following the instruction in the
document entitled

(

Creating 64bit UDL for 64bit PC for MtAdmin.MDB)

On the Desktop INTCAT.INI file - Change the [ODBC] section to reflect the new UDL's

In the [ODBC] section,

RENAME

the IntelliCAT.UDL to IntelliCAT64.UDL where applicable.

Under UserConnect, change the path as noted below:
o

UserConnect="File Name=C:\Program Files (x86)\MagTek\IntelliCAT\Operator64.UDL"

Under WorkQConnect, change the path as noted below:
o

WorkQConnect="File Name=C:\Program Files

 [ ?0DJ7HN?,QWHOOL&$7?&RQWUROOHU8'/

Typical Connection strings in the UDL's

The UDL connections will reference the local Database(s):

IntelliCAT64.UDL connection will use
o

C:\Program Files (x86)\MagTek\IntelliCAT\MtAdmin.MDB

Operator64.UDL connection path will use
o

C:\Program Files (x86)\MagTek\IntelliCAT\Operators\MtAdmin.MDB

Controller64.UDL connection will use
o

C:\Program Files (x86)\MagTek\IntelliCAT\MtAdmin.MDB

12 C

- No Changes are required to the UDL’s if migrating from XP 2.XX to 2.XX (Win 7,

32bit PC)

XP 2.XX to 2.XX (Win 7, 32 bit PC) - The UDL's were copied into the appropriate location in

S

tep 11

.

No changes are required to the UDL's or to the [ODBC] section. The [ODBC] section may reference
either a local setup or a network path structure.

12 D

- 64bit PC users ONLY

Determine if the UDL's connection strings are local or networked (VERY IMPORTANT STEP)
XP 2.XX to 2.XX (Win 7, 64bit PC) - The UDL's were copied into the appropriate location in

S

tep 11

.

However, changes may be required to the UDL's to point to the appropriate Databases depending on
the connection string to the databases. Review the old MtAdmin.MDB which was copied and is now
located in C:\Program Files (x86)\MagTek\IntelliCAT\...

Review the file size of the local MtAdmin.MDB or the Server MtAdmin.MDB

If the Local MtAdmin.MDB is relatively small, IntelliCAT is reporting to a network location.
No changes are required.

If the Local MtAdmin.MDB file in C:\Program Files (x86)\MagTek\IntelliCAT is relatively
large, the UDL's are reporting to the local PC.

Create new UDL's

by following the same steps

as referenced in

S

tep 12B

.

Advertising