<IntelliCAT>| <Migration to Windows 7> | <User Support Document>

Page 6

Step 10 A

- SAVE Old XP 1.XX Local Install Files -

If

S

tep 3

and

4

were performed,

SAVE

the files below.

This was an old XP 1.XX original install. Save files to a thumb drive or network folder.
F

irst

SAVE

, then

EDIT

and

RENAME

where it states Mandatory. If the renaming is not completed as

required, the new installation will fail to work as the MtAdmin.MDB file between versions 1.XX is not

compatible with the 2.XX MtAdmin.MDB file. This is a critical Step as highlighted below

...\IntelliCAT\BinList.TXT

32bit just Copy and Save. 64bit Copy, Save, then edit th

e file

to add (x86)

to Program Files path. Click File, Save, Close

...\IntelliCAT\MtAdmin.MDB

Copy, Save, Mandatory - rename MtAdmin.MDB to

1.X_MtAdmin.MDB after saving

...\IntelliCAT\Operator(s)\MtAdmin.MDB

Copy, if present – Save, Mandatory - rename MtAdmin.MDB to
1.X_OperatorMtAdmin.MDB after saving

...\InteliCAT\MTControllers.DAT

32bit just Copy and Save. 64bit, Copy, Save, then edit th

e file

to add (x86)

to Program Files path. Click File, Save then close.

...\IntelliCAT\Card Layouts\

Copy, Save the entire folder

Step 10 B

- SAVE Old XP 2.XX Local Install Files -

If

S

teps 3

and

4

were NOT performed,

COPY

,

SAVE

the files below. This was an old XP 2.XX original

install. Save files to a thumb drive or network folder.

Step 11

- Copying old files

Copy all of the old files and folders noted above in

S

tep 10

to their respective locations:

32bit copy to C:\Program Files\MagTek\IntelliCAT\... ---

Step 10

A

64bit copy to C:\Program Files (x86)\MagTek\IntelliCAT\... ---

Step 10

B

Click

YES

to

REPLACE ALL

when copying.

Old Files from 2.XX Local Install

Mandatory Action – Save Files below

...\IntelliCAT\BinList.TXT

32bit just Copy and Save. 64bit Copy, Save, then edit t

he file

to add

(x86) to Program Files path. Click File, Save and close.

...\IntelliCAT\MTAdmin.MDB

Copy, Save

...\IntelliCAT\Operators\MTAdmin.MDB

Copy, Save the Operators folder if present

...\InteliCAT\MTControllers.DAT

32bit just Copy and Save. 64bit Copy, Save, then edit th

e file

to add

(x86) to Program Files path. Click File, Save and close.

...\IntelliCAT\Card Layouts\

Copy, Save the entire folder

...\IntelliCAT\*.UDL's

Copy, Save all the UDL's only if the [ODBC] path structure
is referencing the local PC, i.e.
C:\Program

Files\MagTek\IntelliCAT\IntelliCAT.UDL

If the [ODBC] section is referencing a
UNC or Mapped Drive Path structure
i.e. \\server1\MagTek\MagTekUDL\...

DO NOT copy the *.UDL's from the local folder.
And DO NOT TOUCH the networked UDL files.

Old Files From 1.XX Install

Mandatory action - Save Files below