MagTek OMTD 99875144 User Manual
Page 13
![background image](/manuals/413728/13/background.png)
Section 2. Installation
7
The [class flag] parameter gives the option to select specific device classes to configure, remove,
or list. It is a bit flag that can be one or more of the following:
•
<empty> =
Perform operation for all device classes listed below
•
0x01
=
Perform operation for MSR device class
•
0x02
=
Perform operation for MICR device class
•
0x04
=
Perform operation for PIN Pad device class
•
0x08
=
Perform operation for Line Display device class
The configuration utility should be run after MagTek devices are installed, removed, or modified
in Windows NT/2000/XP.
The configuration utility should be run from the DOS command line so that its output may be
seen.
Examples:
omtdcfg -C 0x02 [configure MICR devices]
omtdcfg -L 0x03 [list MICR & MSR devices]
After this, a window listing all of the configured devices will be shown, as indicated below.