Post card string property, Ss_tk1_iso_aba property – MagTek P-SERIES USB User Manual

Page 54

Advertising
background image

P-Series USB Insertion Reader

46

POST CARD STRING PROPERTY

Property ID:

19 (0x13)

Property Type:

String

Length:

0 – 7 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

The default value is no string with a length of zero.

Description:

The value is an ASCII string that represents the device’s post card string.
This string can be 0 – 7 bytes long. This string is sent after all other card data.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


Example Set Post Card_String property Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

04

12

31 32 33


Example Set Post Card_String property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Post Card_String property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

12


Example Get Post Card_String property Response (Hex):

Result Code Data Len

Prp Value

00

03

31 32 33


SS_TK1_ISO_ABA PROPERTY

Property ID:

20 (0x14)

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x25 ‘%’

Description:

This character is sent as the track 1 start sentinel for cards that have track 1
encoded in ISO/ABA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.

Advertising