P-Series USB Insertion Reader

50

Example Set Sensor Blocked Char property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Sensor Blocked Char property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

1C


Example Get Sensor Blocked Char property Response (Hex):

Result Code Data Len

Prp Value

00

01

31


SENSOR UNBLOCKED CHAR

Property ID:

29 (0x1D)

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0

Description:

This character is sent in the sensor field of the card data when the sensor is
unblocked. If the value is 0 no character is sent. If the value is in the range 1
– 127 then the equivalent ASCII character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


Examples follow:

Example Set Sensor Unblocked Char property to ASCII “0” Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

02

1D

30


Example Set Sensor Unblocked Char property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Sensor Unblocked Char property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

1D


Example Get Sensor Unblocked Char property Response (Hex):

Result Code Data Len

Prp Value

00

01

30