PARAMETER ADDRESS LIST

Table 3-3. Parameter Address List

Address

(Hex)

1

Access Default

Value

Parameter

001

R

0x00

Parameter ID #

013 R/W 0x95 Track/ID

Enable

014

R/W

0x63

Track Data Send Flags

015

R/W

'@' (0x40)

Start Sentinel Char for TK2 - 7-bit data

016

R/W

‘!’ (0x21)

Start Sentinel Char for TK3 - CA Driver License

017

R/W

‘+’ (0x2B)

Start Sentinel Char for TK3 - ISO/ABA

018

R/W

‘#’ (0x23)

Start Sentinel Char for TK3 - AAMVA

019

R/W

'&' (0x26)

Start Sentinel Char for TK3 - 7-bit data

01A R/W 18

(0x12)

Char Output Delay ( x 512

μs) default = 9 ms +

01B R/W 50

(0x32)

Special Char

2

Delay ( x 512

μs) default = 25 ms +

01C

R/W

0x00

Pre Card Data code (hex value sent)

3

01D

R/W

0x00

Pre Card Data char (Scan codes sent)

4

01E

R/W

0x00

Post Card Data char (Scan codes sent)

01F

R/W

0x00

Post Card Data code (hex value sent)

020

R/W

0x00

Pre Track char (Scan codes sent)

021

R/W

0x00

Post Track char (Scan codes sent)

022 R/W 0x0D

Terminating

Char + per track/per card flag

023

R/W

0x00

Pre response data code value (hex value sent)

024

R/W

‘W’ (0x57)

Command Prefix Character

025

R/W

0x0D

Post response data char value (scan codes)

026 R/W 0x00 Post

response

data code (hex value sent)

027

R/W

'M' (0x4D)

Command prefix

5

028

R/W

'W' (0x57)

Device ID

029 R/W 0x0D

Command

Terminator

02A

R/W

0x00

Hardware Track mapping

02C

R/W

0x00

Table ID Number (to identify configuration parameters)

02D

R/W

0x00

Table Version Number (to identify configuration parameters)

02E

R/W

0x25

Start Sentinel Character for TK1

080 R/W 0x00 KB

Flag

081-082

R/W

0x00

KB ID #. Not used by MiniWedge. Based on Language ID in
Windows

083-114

R/W

0x00

Flags and scan codes for selected ASCII codes as defined
below.

1FE

R

- -

CRC of parameter table – Low byte

1FF

R

- -

CRC of parameter table – High byte

1

Any address not shown is reserved for future use.

2

A special character is any character with an ASCII value less than 0x20. See Appendix A for character timing.

3

When a "Hex code" is defined, only a single character is sent (e.g., 0x41 sent as 0x41).

4

When a character requiring scan codes is defined, the appropriate set of scan codes is sent for that character

(e.g., 0x41 sent as scan codes representing the letter A).

5

The Command prefix must not be set to a character that could appear in a command since a new command is

started whenever this character is detected.