P001 parameter table id, P013 track/id enable, P014 track data send flags – MagTek MINIWEDGE SWIPE READER User Manual
Page 23
Section 3. Operation
17
Here are definitions of a few of the parameters (Pxxx):
P001 Parameter Table ID #
mod
I I I I I I I
mod
0 – Parameters as set by MagTek
1 – Parameters have been modified from the factory default
I
0-127 – MagTek Parameter Identification #
P013 Track/ID Enable
id
0
T
3
T
3
T
2
T
2
T
1
T
1
Id
0 – Reads Std ISO/ABA cards only
1 – Decodes AAMVA & CA DL/ID Cards also
T
#
00 – Track Disabled
01
–
Track
Enabled
10 – Track Enabled/Required (Error if blank)
Default: 0x95 = Include Driver licenses, all 3 tracks enabled but not required.
P014 Track Data Send Flags
BAT SS ES LRC NBR LC Er Er
BAT
0 – Normal Basic Assurance Test (Twice)
1 – Single BAT (for some special terminals)
SS
0 – Don’t send Start Sentinel for each track
1 – Send Start Sentinel for each track
ES
0 – Don’t send End Sentinel for each track
1 – Send End Sentinel for each track
LRC 0 – Don’t send LRC for each track
1 – Send LRC for each track