Campbell Scientific CR10X Measurement and Control System User Manual
Page 122

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
8-14
20:
Covariance/Correlation (P62)
1:
5
No. of Input Locations
2:
5
No. of Means
3:
5
No. of Variances
4:
0
No. of Std. Dev.
5:
4
No. of Covariance
6:
2
No. of Correlations
7:
300
Samples per Average
8:
1
First Sample Loc [ W1 ]
9:
20
Loc [ MEAN_W1 ]
21:
Covariance/Correlation (P62)
1:
5
No. of Input Locations
2:
5
No. of Means
3:
5
No. of Variances
4:
0
No. of Std. Dev.
5:
9
No. of Covariance
6:
2
No. of Correlations
7:
300
Samples per Average
8:
11
First Sample Loc [ W2_i ]
9:
36
Loc [ mean_W2 ]
22:
Real Time (P77)
1: 0110
Day,Hour/Minute
23:
Sample (P70)
1:
35
Reps
2:
20
Loc [ mean_W1 ]
TABLE 8.10-4. Thirty Minute Output From Example
01 119
02 DAY
03 HRMIN
04 M(W1)
05 M(U1)
06 M(V1)
07 M(Ta1)
08 M(e1)
09 V(W1)
10 V(U1)
11 V(V1)
12 V(Ta1)
13 V(e1)
14 CV(W1,U1) 15 CV(W1,V1) 16 CV(W1,Ta1)
17 CV(W1,e1) 18 CR(W1,U1)
19 CR(W1,V1) 20 M(W2)
21 M(U2)
22 M(V2)
23 M(Ta2)
24 M(e2)
25 V(W2)
26 V(U2)
27 V(V2)
28 V(Ta2)
29 V(e2)
30 CV(W2,U2) 31 CV(W2,V2) 32 CV(W2,Ta2)
33 CV(W2,e2) 34 CV(U2,V2)
35 CV(U2,Ta2) 36 CV(U2,e2) 37 CV(V2,Ta2) 38 CV(V2,e2)