Campbell Scientific CR10X Measurement and Control System User Manual
Page 247

APPENDIX B. CONTROL PORT SERIAL I/O INSTRUCTION 15
B-15
11:
1
Multiplier
12:
0
Offset
06:
P
End Table 1
Input Location Labels:
1:VALUE #1
4:VALUE #4
7:VALUE #7
10:VALUE #10
2:VALUE #2
5:VALUE #5
8:VALUE #8
11:COUNTER
3:VALUE #3
6:VALUE #6
9:VALUE #9
12:_________
CR10X#2 PROGRAM - RECEIVE DATA
*
3
Table 3 Subroutines
01:
P85
Beginning of Subroutine
01:
98
Subroutine Number
02:
P15
Control Port Serial I/O
01:
1
Repetitions
02:
1
Configuration code
RS-232, 1200 bd
03:
0
CTS/Delay before send
04:
6
C6 RTS/DTR
RXD = C7 (code could be 76)
05:
0
Output start location
06:
0
Number of locations to send
07:
13
Input termination character
Terminate on carriage return
08:
75
Max characters to receive
09:
200
Delay for CTS/input
Wait 2 seconds for input
10:
11
First input location
Store VALUE #1 in Location 11, #10 in 20
11:
1
Multiplier
12:
0.0000
Offset
03:
P95
End
Input Location Labels:
11:VALUE #1
16:VALUE #6
12:VALUE #2
17:VALUE #7
13:VALUE #3
18:VALUE #8
14:VALUE #4
19:VALUE #9
15:VALUE #5
20:VALUE #10