Campbell Scientific CR10X Measurement and Control System User Manual
Page 245

APPENDIX B. CONTROL PORT SERIAL I/O INSTRUCTION 15
B-13
02:
P89
If X<=>F
START: Limit testing
01:
1
X Loc AIR, mb
02:
3
>=
If reading is
>
1300 mb
03:
1300
F
04:
11
Set high Flag 1
then set Flag 1
high
03:
P89
If X<=>F
01:
1
X Loc AIR, mb
02:
4
<
If reading is < 800 mb
03:
800
F
04:
11
Set high Flag 1
then set Flag 1
04:
P91
If Flag/Port
If Flag
1 is set,
01:
11
Do if flag 1 is high
02:
30
Then Do
do the following.
05:
P86
Do
Output time of failure
01:
10
Set high Flag 0 (output)
06:
P77
Real Time
01:
110
Day,Hour-Minute
07:
P70
Sample
Output out of range reading
01:
1
Rep
02:
1
Loc AIR, mb
08:
P86
Do
Set Intermediate Processing
01:
19
Set high Flag 9
Disable Flag
09:
P86
Do
Set Flag 1 low
01:
21
Set low Flag 1
10:
P95
End
End of If Flag Then Do
11:
P92
If time is
Output mb twice/day
01:
0
minutes into a
02:
720
minute interval
03:
10
Set high Flag 0 (output)
12:
P77
Real Time
01:
110
Day,Hour-Minute
13:
P71
Average
01:
1
Reps
02:
1
Loc AIR, mb
14:
P
End Table 1
Input Location Labels:
1:AIR, mb