22 fs1 collected, 23 fs2 to collect, 24 fs2 collected – Campbell Scientific CSIOPC Software User Manual

Page 19: 25 logger ver, 26 watchdog err

Advertising
background image

CSIOPCServer

Description: Reflects the total number of final storage values that need to be

collected from final storage area one of a classic datalogger if collection is
active for that area. If collection is not active for that area, this statistic
reflects the last count that should have been collected.

6.3.2.22 FS1 Collected

Type: uint4

Applies to: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X

Description: Reflects the total number of final storage values that have been

collected from a classic dataloggers final storage area one.

6.3.2.23 FS2 to Collect

Type: uint4

Applies to: CR10, CR10X, CR510, CR23X

Description: Reflects the total number of final storage values that need to be

collected from final storage area two of a classic datalogger if collection
is active for that area. If collection is not active for that area, this statistic
reflects the last count that should have been collected.

6.3.2.24 FS2 Collected

Type: uint4

Applies to: CR10, CR10X, CR510, CR23X

Description: Reflects the total number of final storage values that have been

collected from a classic dataloggers final storage area two.

6.3.2.25 Logger Ver

Type: uint4

Applies to: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X

Description: Relates the datalogger interface version as given in the

datalogger’s response to the “A” command.

6.3.2.26 Watchdog Err

Type: uint4

Applies to: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X

Description: Relates the datalogger watch dog error count as given in the

classic datalogger’s response to the “A” command.