6.3.2.32 Lith Batt Volt

Type: float

Applies to: CR10X, CR500, CR510, CR23X

Description: Reports the lithium battery voltage on classic dataloggers. This

value is extracted from the results of the “A” command.

6.3.2.33 Table Defs State

Type: enumeration

Applies to: CR10T, CR10X-TD, CR510T, CR23X-TD, CR9000, CR5000,

CR10X-PB, CR510-PB, CR23XPB, CR200 Series, CR800, CR1000,
CR300

Description: Relates the current state of cached table definitions for a table

based (BMP1, BMP3, or BMP5) datalogger. The following values are
defined:

1. none - No table definitions have been received from the datalogger.

2. current – The server’s table definitions are believed to be current for

the datalogger.

3. suspect – A collection attempt has returned an invalid table

definitions code. The server needs to verify the table definitions for
the logger.

4. getting – Indicates that the server is currently trying to get the table

definitions from the datalogger

5. invalid – The table definitions are known to be invalid and need to be

manually refreshed before collection can continue.

6.3.3 Server Statistics

The statistics relating to the host machine for the server or to the operation of
the server as a whole can be found in a the table named
“__LgrNet____controller__”. These statistics are updated every ten seconds.
There is only one row defined for the table. The statistics available in this table
are as follows:

6.3.3.1 Disc Space Avail

Type: int8

Description: Relates how many bytes are free on the volume where the

server’s working directory resides.