background image

Appendix D. Digital Cellular Modem to MD485 Network

2. TRANSPARENT COMMUNICATION

PC-Modem----Cell Tower Redwing-null modem-MD485-MD485-DL

LoggerNet Setup

a. Setup:

TAPIPort
TAPIRemote
PakBus Port (PakBus dataloggers only)
CR1000

b. TAPIPort – TAPI line corresponding to PC's modem

c. TAPIRemote – input digital cellular modem's phone number

d. PakBus Port – defaults (PakBus dataloggers only)

e. CR1000 – default settings, schedule collections as desired

MD485 Configuration

a. Base MD485

1) Active Ports – “RS-232 and RS-485”
2) Communication Mode – “Transparent Communication”
3) RS-232 Port Configuration – Desired baud rate
4) RS-485 Port Configuration – Desired baud rate

b. Remote MD485

1) Active Ports – “CS I/O and RS-485”
2) Communication Mode – “Transparent Communication”
3) CS I/O Port Configuration – Modem Enable
4) RS-485 Port Configuration – Desired baud rate

3. MD9

EMULATION

(POINT-TO-MULTIPOINT)

PC-Modem----Cell Tower Redwing-null modem cable-MD485 ------MD485-DL1

------MD485-DL2

LoggerNet Setup

a. Setup:

TAPIPort
TAPIRemote
MD9Base
MD9Remote
CR10X
MD9Remote_2
CR10X_2

b. TAPIPort – TAPI line corresponding to PC's modem