Appendix D. Digital Cellular Modem to MD485 Network

b. Remote

MD485s

1) Active Ports – “CS I/O and RS-485”
2) Communication Mode – “MD9 Emulation” with address 1, 2,

etc. (unique for each remote MD485 and must agree with
respective MD9 in device map)

3) CS I/O Port Configuration – Modem Enable
4) RS-485 Port Configuration – Desired baud rate

4. PAKBUS

NETWORKING

PC-Modem ---Redwing--null modem---MD485 ----------MD485-DL1

---------

--MD485-DL2

LoggerNet SETUP

a. Setup:

TAPIPort
TAPIRemote
PakBus

Port

CR1000
CR1000_2

b. TAPIPort – TAPI line corresponding to PC's modem

c. TAPIRemote – input digital cellular modem's phone number

d. PakBus Port – defaults

e. Dataloggers – corresponding PakBus address, other setting default,

schedule collections as desired