3 terminal mode – Campbell Scientific PWS100 Present Weather Sensor User Manual

Page 38

Advertising
background image

Section 7. Operation

configuration options. These are discussed below within the context of setting
up the sensor using a terminal emulator.

7.3 Terminal Mode

In normal operating mode the sensor will respond to a number of “root”
commands, shown in Table 7-1. Those commands allow the configuration of
the sensor in a non-interactive fashion, the polling of data and also switching
the sensor into an interactive user menu mode.

They are accessed via the command TERM PWS_1d Password

Commands are entered in the format ‘Command Pws_1d Password

TABLE 7-1. Command Set

Command Description

PASSWORD Sets

user

password

HELP*

Gives a list of available commands

OPEN* Activate

user

menu

TERM

Enter command mode

CLOSE Exit

command

mode

MSEND* Poll

messages

MSET

Set message parameters

HDATA

Retrieve historical particle data from sensor

SETPARAM Set

weather

parameters

FUZZY DIAG* Extra particular information (see Section 7.5.2)

CONFIG View

system configuration

SETCONFIG

Set system configuration

LOADOS

Load a new operating system

DIAGSET

Set diagnostic test parameters

DIAG

Run diagnostic test

TIME

Display or set time and date

RSENSOR

Receive remote sensor values (T °C and H %)

RESET Reset

hardware

XHMDATA

Historic `MSET’ data download using Xmodem

HMDATA

Output historic data to the command line

RUNDISC

Rotate the calibration disc for test / demonstration
purposes


*These commands are available outside terminal mode.

The most commonly used commands are MSEND, HELP and OPEN.

7-2