Campbell Scientific RavenXTG Sierra Wireless Cellular Modem User Manual

Page 29

Advertising
background image

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem

Verify the APN has been entered in the NETAPN and +CGDCONT fields as
shown above (where I2GOLD is the APN).

If the modem answers but you do not get a connection to the datalogger:

1. Check your connection to the datalogger.

a. An SC932A or SC105 interface is required to connect the modem to a

datalogger’s CS I/O port (Section 4, Configuration). The default
settings for SC105 (OS > 4) can be used with the RavenXTG when
the modem is configured for 115200 baud (baud rate is set by the
template file).


Baud rate of the SC105 must match the baud rate in the modem
(which has to be supported by the datalogger). SC105 settings for use
with the RavenXT are listed below, which are configured using the
DevConfig utility.

SC105 settings for the RavenXT:

CS I/O Mode: SDC Address 7
RS-232 Mode: Modem
Baud Rate: 115.2K or 9600 baud depending on datalogger model
8 data bits, 1 stop bit, no parity

Make sure the modem is connected to the “DCE Device” connector
on the SC932A, or the “Modem” connector on the SC105.

b. A null modem cable is required to connect the modem to a

datalogger’s RS-232 port. No other interface is required.

23

Advertising