Configuration, 1 base station requirements for ravenxtg, 2 datalogger site equipment – Campbell Scientific RavenXTG Sierra Wireless Cellular Modem User Manual

Page 9: Base station requirements for ravenxtg, Datalogger site equipment

Advertising
background image

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem

Typical Current Drain (at 12 Vdc): 50 mA dormant (idle for 10 to 20 seconds),

120 mA transmit/receive

Input Voltage Range:

6 to 28 Vdc

Operating Temperature Range: –30° to +65°C

Operating Humidity Range:

5% to 95% RH non-condensing

Status LEDs:

Power, Network, Signal, Activity

Dimensions

Width:

7.6 cm (3 in)

Depth:

2.5 cm (1 in)

Length:

10 cm (4 in)

Weight:

<0.5 kg (<1 lb)

4. Configuration

4.1 Base Station Requirements for RavenXTG

PC running Campbell Scientific’s LoggerNet or PC400 software, with access
to the Internet.

4.2 Datalogger Site Equipment

• RavenXTG modem with power cable (included with modem).

• Datalogger—21X, CR510, CR10(X), CR23X, CR7, CR1000, CR5000,

CR3000, CR800.

• Modem Interface

If connecting to CS I/O port:

SC105 or SC932A Interface—connects the modem to the 21X,
CR510, CR10(X), CR7, or other dataloggers’ CS I/O port.

The SC105 must be configured for use with the modem using the
Device Configuration Utility. Settings should be:

CS I/O Mode: SDC Address 7
RS-232 Mode: Modem
Baud Rate: 115.2K or 9600 baud depending on datalogger model
8 data bits, 1 stop bit, no parity

If connecting to RS-232 port:

PN 18663 Null Modem Cable—connects the modem to the
CR23X, CR3000, CR800, CR2XX, CR1000, or CR5000 RS-232
port.

3