Appendix E. Troubleshooting Flowchart

PPP or Serial Server

Can’t connect, Network light is solid... (cont.)

Have mobile terminated IP

Was correct template loaded

into AceManager?

Did you click “Write” and

then “Reset”?

Verify Dport (AceManager;

Misc group) is set to 3001.

Verify baud rate is correct for

datalogger.

In AceManager (Status

group); Check Host Serial

Bytes Sent/Received — try to

connect to logger — check

Host sent/received again.

Is DPort (AceManager; Misc

Group) set to 3001?

Or 6785?

Is LoggerNet trying to

connect to same?

Could be wrong baud rate.

Should be correct if the

correct template was loaded,

written and the modem

reset.

If sent increases, but

received does not, almost

always a physical

connection between the

logger and modem, not the

modem.

If LoggerNet is set to

connect to the DPort

of the modem, it will

connect only to the

modem, rather than

through the modem

to the logger.

PPP

Serial Server

Yes

Yes

E-3