SC-USB USB to CS I/O Opto-isolated
Interface

The SC-USB is designed to allow Campbell Scientific dataloggers to communicate directly
with computers fitted with a USB interface. It provides an isolated connection which can
also operate at higher speeds than conventional RS-232 connections.

1. Introduction

The SC-USB is optically isolated thus preventing possible noise pickup
associated with PC power supplies and ground connections. It also supports
synchronous communications modes, available in some models of dataloggers,
which allow multiple devices to be connected in parallel. The SC-USB can be
used in place of an SC32B interface. The SC-USB also has the potential for
high-speed data transfer to the PC at up to 1 MBit/second where the datalogger
supports it.

Originally, the SC-USB was fitted with an integrated USB cable. At the end of
2009, the SC-USB was redesigned to include a connector instead of the
integrated cable. A 17648 USB cable attaches to the new connector. This
cable is shipped with the SC-USB.

The SC-USB will appear in PC software as a new virtual serial port, allowing it
to be used with many software packages.

The SC-USB PC drivers support various operating systems including Windows
98/ME, 2000, XP, Vista, and 7. The SC-USB is shipped with a software CD
containing suitable drivers and a set-up/programming utility called Sc-USB.exe
which can be found in a directory named ‘Utility’ on the CD. The CD also
contains a comprehensive help file, and manual. These files can be accessed
directly from the CD, if required, by double-clicking on the icon 'index'.

The SC-USB will normally operate ‘straight from the box’ for most
applications using the default settings. However, you can change the baud rate,
the communication rate, and its USB ID by using the Sc-usb.exe set-up utility
provided (see Section 3.2). This utility can also be used to upgrade the
SC-USB’s operating system.

Please check with Campbell Scientific if you wish to use the SC-USB with a
CR9000X.

If you are using a CR5000 datalogger, make sure the datalogger
operating system is version 2.0 or later as this will enable the
highest communication speeds. For older versions set the
SC-USB to work in ME Comms Mode (see Section 3.2).

NOTE