SC-USB USB to CS I/O Opto-isolated Interface

• PC software compatibility PC200W, PC400, LoggerNet, RTDAQ and

most other packages that support virtual serial ports.

• Active current consumption less than 19 mA (current drawn from

datalogger).

• Quiscent current consumption less than 80 µA (current drawn from

datalogger).

2.3 General Specifications

• Height: 0.8 in (2 cm)

Width: 1.6 in (4 cm)
Length: 3.0 in (7.5 cm)

• Weight: 3.0 oz
• Operating temperature range -25° to +50°C
• EMC compliance: complies with EN61326:1998 (see Section 5.3)
• Driver support for Windows 98 / ME / 2000 / XP / Vista / 7 supplied on

CD (Contact Campbell Scientific for other drivers)

2.4 Ships With

• 17648 USB cable for connection to the PC’s USB port.
• SC12 CS I/O cable for connection to the datalogger.
• Driver CD containing setup utility and manual.
• ResourceDVD.

3. Using SC-USB Driver and Setup CD

3.1 Drivers Installation

The installation procedure is straightforward. The Windows set-up wizard will
guide you through the installation steps as indicated below.

This guide assumes that you are installing the drivers onto a ‘clean’ system
(i.e., one on which similar drivers have not been installed previously). If this is
not the case, then you should first uninstall the existing drivers using the
standard Windows procedure (see below). If upgrading your drivers from a
previous version of SC-USB driver, it is also important to deinstall the
previous drivers first to avoid conflicts.