Perform the following procedure to configure RMON alarms.

1. From the main menu on the left side of the page, click the RMON

folder.

The RMON folder expands.

2. From the RMON folder, select Alarm.

The RMON Alarm Settings Page is displayed. See Figure 108.

Figure 108. RMON Alarm Settings Page

3. The following fields are listed:

Index: This parameter specifies the ID number of the new group. The
range is 1 to 65535.

Interval: This parameter specifies the time (in seconds) over which the
data is sampled. Its range is 1 to 2147483647 seconds.

Variable: This parameter specifies the RMON MIB object that the
event is monitoring.

Sample type: This parameter defines the type of change that has to
occur to trigger the alarm on the monitored statistic. There are two
choices from the pull-down menu - Delta value and Absolute value.
The Delta setting compares a threshold against the difference between
the current and previous values of the statistic, while the Absolute
setting compares a threshold against the current value of the statistic.