Allied Telesis AlliedView-EMS 4.0.2 Device-Manager User Manual
Page 49

AlliedView™-EMS 4.0.2 DEVICE MANAGER USER’S GUIDE
Page 49 of 124
•
Condition - Threshold configured on the variable. If the variable's value exceeds the
threshold, an action is executed. You can configure the type of action to execute
in the User Action tab of the Option menu.
Note
- Current, Max, Min and Average values are zero before the first polling. After the first
polling, they all have the same value. Once the threshold is reached, the corresponding row
is highlighted with a red background. Note that thresholds can only be set for MIB variables
of type GAUGE, INTEGER, COUNTER, GAUGE32, INTEGER32, COUNTER32,
or COUNTER64.
Display Threshold
Add button (Green 'plus' icon)
Adds a new threshold definition.
Remove button (Blue 'X' icon)
Removes the selected threshold.
Edit button ('note and pen' icon)
Edits the selected threshold.
5.2.6 Current Log
Displays the event log. It records events such as Device Manager start up, reception
of traps, or threshold events.