AT-RPS3104 and AT-PWR3101 Installation Guide

33

Replacing the AT-PWR3101 Module

To remove or replace a failed AT-PWR3101 module, perform the
following procedure:

1. Turn the appropriate On/Off power switch on the back panel of the

AT-RPS3104 system to the Off position. Each module slot in the
AT-RPS3104 system has a separate power switch on the back panel.

Note

The AT-PWR3101 module is not hot-swappable. The On/Off power
switch must be set to the Off position.

Note

When replacing an AT-PWR3101 module, you do not need to
disconnect the corresponding power cable and RPS cable from the
back panel of the AT-RPS3104 system.

2. Using a # 1 Phillips screwdriver, loosen the two captive screws that

secure the failed AT-PWR3101 module in the AT-RPS3104 system
(see Figure 23).

Figure 23. Loosening the Captive Screws on the AT-PWR3101 Module

STATUS

AT-PWR3101

POWER

FAUL

T

STATUS

AT-PWR3101

POWER

FAUL

T