At-cv1kss line card dip switches – Allied Telesis AT-S70 User Manual
Page 271

AT-S70 Management Software User’s Guide
271
AT-CV1KSS Line Card DIP Switches
The AT-CV1KSS line card features one set of DIP switches labeled
“SW1”, as shown in Figure 91.
Figure 91. DIP Switch Set on an AT-CV1KSS Line Card
The DIP switches in the SW 1 DIP switch set allow you to set the operating
mode of the line card. For information about the operating modes, refer to
“Configuring the Line Card Operating Mode” on page 67.
Table 9 shows how to enable the operating mode on an AT-CV1KSS line
card by setting the DIP switches in the SW 1 DIP switch set.
“X” means that the DIP switch position can be ON or OFF.
AT-CV1KSS
LK
AT
S
F
P
SW1
ON
1 2
3 4
4 3
2 1
SW 1 DIP Switch Set
Table 9. SW 1 DIP Switch Set (Operating Mode) for the AT-CV1KSS Line
Card
Operating Mode
DIP 1
DIP 2
DIP 3
Smart MissingLink (SML)
OFF
ON
X
MissingLink™ (ML)
ON
OFF
X
Link Test (default)
OFF
OFF
X
Manufacturing Default Settings
OFF
OFF
OFF