Configuring the local console settings, Figure 23. at-cm70s local console menu – Allied Telesis AT-S70 User Manual
Page 74

Chapter 5: Working with Line Cards
74
Configuring the
Local Console
Settings
To change the TDM (time-division multiplexing) port parameters on the
AT-CM70S line card from the local console, perform the following
procedure:
1. Connect PC serial port to the Line card local console.
Figure 23 is displayed upon boot up.
You may need to turn the “Local Echo” setting on your AT-CM70S
serial port terminal settings to ON.
Figure 23. AT-CM70S Local Console Menu
The AT-CM70S Local Console Menu items and options are described
below:
Boot Configuration
Displays the AT-CM70S line card local console boot configuration.
Boot Data From
- Manufacture (default)
- Customized
LIU Mode
- T1
- E1
Current Status
Displays the AT-CM70s line card local console current status on all 4
channels with the following information:
Rec Sens Set
- Long Haul (default)
- Limited Long Haul
Line Build Out
T1 DSX-1(0 to 133ft)/0dB CSU (default)