14

Planning the Installation

Be sure to observe the following guidelines when planning the installation of
your Ethernet switch.

The end node connected to the fiber optic port on an AT-FS201ST or
AT-FS202SC switch must be able to operate at 100 Mbps.

The end node connected to the twisted pair port(s) can operate at
either 10 Mbps or 100 Mbps.

The end node connected to a port on the switch can be a network
adapter card, repeater, router, hub, or another switch.

The twisted pair cabling must be kept away from sources of electrical
noise, such as radios, transmitters, power lines, broadband amplifiers,
electrical motor, and fluorescent fixtures.

Refer to Table 3 for the cabling specifications for the twisted pair
port(s).

Table 3 10/100Base-TX Twisted Pair Cabling Specifications

Operating Mode

Cable Type

Maximum

Distance

10Base-T

Shielded or unshielded Category 3 or better

100 m (328 ft)

100Base-TX

Shielded or unshielded Category 5 or better

100 m (328 ft)