Connectivity Testing

1. Connect each port to a node or workstation. Then connect the power cord.

2. Verify that the Link LEDs for Port 1 and Port 2 are lit.

If the Link LED does not light (TX):

Verify that the switch’s port matches the speed selection of the device
attached to the other end.

The switch settings are represented by each port’s LEDs. For
troubleshooting purposes, determine the current port settings, for
example auto-negotiation, 10 or 100 Mbps (speed) duplex mode.

Change the MDI/MDI-X switch setting on the port and see if a link
occurs. If not, put the switch back to its original configuration.

If the Link LED does not light (FX):

Make sure the remote end of the fiber optic cable is connected to a
100Base-FX device.

Swap the near end fiber cable receive/transmit connectors.

Is the Link LED Lit?

The Link LEDs light when a proper connection between the corresponding 10/
100Base-TX or 100Base-FX port and the equipment connected to it is
established. If this LED is not lit, check for the problems listed as follows and
make corrections as necessary.

1. Problem 1:

The cable has been cut, damaged, or is the wrong type of cable.

Solution 1:

— Try making the connection with a different cable. Be sure you are

using an undamaged cable of the correct type.

2. Problem 2:

Connected equipment is not turned ON or is not operating properly.

Solution 2:

— Check the connected equipment (computer, another switch, etc.)

and turn ON the power.

— Make sure that the SPEED and Duplex Mode for each port of the

switch match the settings of the attached computer or additional
switch.