Installing the Switch

16

Refer to Table 5 for the cabling specifications for the fiber optic port
operating in half-duplex mode.

1. The total distance of the fiber optic lengths cannot exceed the limits stated in the table. Each media converter used

inline within a single collision domain reduces the overall segment length by 40 m (131 ft).

Selecting a Site

Be sure to observe the following requirements when choosing a site for your
switch.

Select a site that is dust-free and moisture-free.

Be sure that the site will allow you to easily access the fiber optic and
twisted pair cables and the power cord.

Use dedicated power circuits or power conditioners to supply reliable
power to the device.

Table 5 100Base-FX Fiber Optic Ports (Half-duplex) For Port 2

1

Number of Media
Converters

Connected Devices

Maximum Distance

One Media Converter Inline

Switch to switch

372 m (1,221 ft)

Workstation to switch

372 m (1,221 ft)

Switch to Class I repeater

137 m (450 ft)

Switch to Class II repeater

185 m (607 ft)

Two Media Converters
Inline

Switch to switch

332 m (1,089 ft)

Workstation to switch

322 m (1, 089 ft)

Switch to Class I repeater

97 m (318 ft)

Switch to Class II repeater

145 m (476 ft)