Power led is off, Fault led is on, Power led is off fault led is on – Allied Telesis AT-8324 User Manual
Page 71
AT-8316F and AT-8324 Installation Guide
71
Power LED is
OFF
If there is no power to the switch, it cannot function.
A Power LED that is OFF can indicate:
# A loose power cord.
# Power supply failure, malfunction, or loss of power to the
power supply.
# A power supply voltage below acceptable levels.
# A high switch temperature due to fan failure or extreme
ambient temperature.
Perform the following steps in sequence; you need not proceed to
the next step if the problem is resolved:
1. Secure the power cord to the power source and check the Power
LED to see if it is ON.
2. Ensure that the voltage is within the required levels in your region.
3. Logon to Omega and run
Diagnostics
if you can
(
Administration>Diagnostics
) and record any failures.
4. Contact Allied Telesyn’s Technical Support and report the results
of the tests.
Fault LED is ON
This might indicate problems with the network management
software, such as:
# An unsuccessful software download
# A failure of the power-on diagnostics
Perform the following steps in sequence; you need not proceed to
the next step if the problem is resolved:
1. Reset the stack either by:
— Pressing the RESET button on the front panel of the
switches in the stack, or
— Selecting
Administration>Reset and restart
the system
from Omega, if you can.
2. Make sure the RS-232 connection from the local terminal or PC to
the master switch is secure; change the cable if necessary.
If you cannot access the switch locally because of a faulty
RS-232 connection, try to access the switch through a web
browser or remotely with Telnet or an SNMP network
management program until the problem is fixed.