Table B-1 lists the technical specifications for the AT-8316F and
AT-8324 switches.
Table B-1 Technical Specifications
Physical Specifications
Dimensions (H x W x D)
Weight
Base Unit
6.48 cm x 42.93 cm x 35.60 cm
(2.55 in x 16.9 in x 14.0 in)
5 kg (11 lbs)
Required ventilation on all sides
19 cm (7.5 in)
Environmental Specifications
Operating temperature
0° C to 40° C (32° to 104° F)
Storage temperature
-25° C to 70° C (-13° to 158° F)
Operating humidity
5% to 95% non-condensing
Operating altitude range
up to 3,000 m (9,843 ft)
Power Specifications
Maximum power consumption
95 W
AC input voltage
100-120/200-240VAC~ +64/2A, 50/60Hz.
Frequency
50/60 Hz
±
3 cycles of nominal input frequency
Safety and Electromagnetic Emissions Certifications
Safety: UL 1950
CSA 22.2 No. 950
EN 60950 (TUV)
EMI: FCC Class A
EN55022 Class A
Immunity: EN50082-1
Quality and Reliability:
MTBF > 50,000 hrs
MTTR < 1/2 hr
DOA < 1%