Resetting to factory default values, Displaying system parameter settings, Disabling an alarm – ADC H2TU-C-231 User Manual

Page 18: Loopback modes

Advertising
background image

Provisioning

LTPH-UM-1109-01, Issue 1

10

January 9, 2002

H2TU-C-231 List 2

Resetting to Factory Default Values

All user options for the H2TU-C-231 List 2 (

Table 6 on page 18

) can be set to the factory default values using the

MODE and SEL pushbuttons. To set the user options to their default values:

1

Press the SEL pushbutton for 6 seconds until the following message appears:

DFLT NO

2

Press the SEL pushbutton while the

DFLT NO

message is displayed.

The message changes to

DFLT YES

indicating the factory default values are now in effect and the display

returns to the normal mode.

To terminate the

DFLT

mode without setting the factory default values, do one of the following:

Press the MODE pushbutton to return to the normal display mode.

Wait 30 seconds for the unit to return to the normal display mode.

Displaying System Parameter Settings

To scroll through the current settings of all system parameters, press the MODE pushbutton for 3 or more seconds.
The H2TU-C-231 List 2 displays the following parameters:

Software version number

List number

Type of frame pattern received from the DSX-1

Line code of the signal received from the DSX-1

All user-configured parameter settings

Loop attenuation threshold setting

Margin alarm threshold setting

Disabling an Alarm

If the system is in a Minor alarm state, the alarm relay can be disengaged by pressing the SEL pushbutton. This
activates the Alarm Cutoff (ACO) indication. For more information about alarms, see

“System Alarms” on

page 40

.

Loopback Modes

See

“Loopback Operation” on page 43

for instructions on using the MODE and SEL pushbuttons to activate

loopbacks.