Appendix B - Functional Operation

H2TU-C-231 List 2

January 9, 2002

59

A

PPENDIX

B - F

UNCTIONAL

O

PERATION

ADC HDSL2 technology provides full-duplex services at standard DS1 rates over copper wires between an
H2TU-C and an H2TU-R, which comprise one HiGain HDSL2 system. HiGain HDSL2 systems use Overlapped
Pulse Amplitude Modulation Transmission with Interlocking Spectra (OPTIS) transceiver systems to establish
full-duplex, 1.552 kbps data channels between the H2TU-C-231 and a remotely located H2TU-R.

A block diagram of the H2TU-C-231 is shown in

Figure 33

. The H2TU-C-231 receives a 1.544 Mbps DSX-1 data

stream from the DSX-1 digital cross-connect interface. The H2TU-C-231 contains a DS1 frame synchronizer
controlled by an 8-bit microprocessor that determines the type of framing on the DS1 stream and synchronizes to
it. The H2TU-C-231 recognizes SuperFrame (SF) or Extended SuperFrame (ESF) framing. When the data is
unframed, the H2TU-C-231 arbitrarily defines a frame bit.

Figure 33.

H2TU-C-231 List 2 Block Diagram

T

IMING

The low-loop wander (0.5 UI max) of an H2TU-C-231, when used with remote units, allows the circuit to be used
in all critical timing applications, including those used to transport Stratum 1 timing.

G

ROUND

F

AULT

D

ETECT

The H2TU-C-231 has a Ground Fault Detect (GFD) circuit which detects a ground or a resistive path to ground
on any wire of the HDSL2 loop. This makes the product compliant with the Class A2 requirements of GR-1089.

HDSL 2

XCVR

Microprocessor

Power Supply

B

A

B

Tip

+

_

34

35

Ring

HDSL 2

SPAN

-48Vdc 39

15

16

19

44

Ground

32

LEDs

A

RS-232 (front panel)

42

43

Tip

Ring

D

S

X

1

OUT

49

50

20

21

Tip 1

Ring 1

Alarms

LINE

LINE

IN

D

S

X

1

BRG

BRG

Pre-equalizer

Select

T1

Framer

MODE SEL

Fuse alarm

Management bus

46

-180 Vdc

Power

Supply

(Ground isolated

and ground fault detect)