H2tu-c-231 list 2 standard config menu options – ADC H2TU-C-231 User Manual

Page 25

Advertising
background image

LTPH-UM-1109-01, Issue 1

Provisioning

H2TU-C-231 List 2

January 9, 2002

17

Table 5

describes the Standard Config menu options and

Table 6 on page 18

describes the ADC Config menu

options. Selections in bold type indicate factory default settings.

Table 5.

H2TU-C-231 List 2 Standard Config Menu Options

Standard Config
Menu Options

Front-Panel
Display
Code

Selection

Description

Loopback
Timeout

LBTO

NONE

Disables automatic time-out cancellation of all loopbacks.

20

Sets automatic cancellation of all loopbacks to 20 minutes after initiation.

60

Sets automatic cancellation of all loopbacks to 60 minutes after initiation.

120

Sets automatic cancellation of all loopbacks to 120 minutes after initiation.

8 hr

Sets automatic cancellation of all loopbacks to 8 hours after initiation.

24 hr

Sets automatic cancellation of all loopbacks to 24 hours after initiation.

Loop Attenuation
Threshold

LATT

0 through
40 dB

Determines the maximum loop attenuation before an alarm is declared. The
loop attenuation threshold can only be set through the maintenance screens.
Zero disables the alarm.

35 dB

Default value.

Margin Threshold

MARG

0 to 15 dB

Determines the minimum allowable margin below which a system alarm can
occur. The Margin (Alarm) Threshold can only be set through the
maintenance screens. Zero disables the alarm.

4 dB

Default value.

DS1 Frame
Formatting

FRMG

AUTO

Configures the HiGain HDSL2 system to operate in an auto-framing (AUTO)
mode in which it continuously searches the input DS1 bit stream for a valid
SF or ESF frame pattern. Both line and path performance parameters are
maintained. Unframed payloads will cause the ES-P and SES-P counters to
increment.

SF

Configures the HiGain HDSL2 system to search for the SF framing pattern at
its DS1 input.

ESF

Configures the HiGain HDSL2 system to search for the ESF framing pattern at
its DS1 input.

UNFR

Configures the HiGain HDSL2 system to operate in an unframed mode. This
mode disables the auto framing process and forces the system to function as
a transparent bit pipe. Only line parameters are considered when monitoring
DS1 performance.

DS1 Line Coding

See

“DS1 Line

Coding (DS1)
Option” on
page 19

.

DS1

AUTO

The H2TU-C-231 and H2TU-R monitor the incoming DS1 bit streams for the
B8ZS code. If the H2TU-R detects this code, the H2TU-C enters B8ZS output
mode. The H2TU-C reverts back to AMI output mode if no B8ZS codes are
received at the H2TU-R input for 5 seconds. Similarly, when the H2TU-C
detects the B8ZS code, the H2TU-R enters B8ZS mode and returns to AMI
mode if no B8ZS code is received at the H2TU-C input for 5 seconds.

B8ZS

Places both the H2TU-C-231 and H2TU-R into B8ZS mode.

AMI

Places both the H2TU-C-231 and H2TU-R into AMI mode.

H2TU-C
Equalization

See

“H2TU-C

Equalization
(EQL) Option.” on
page 20

.)

EQL

EXT

Disables the H2TU-C internal equalizer, allowing connection of external
equalizer hardware.

0

Sets the Equalizer to DSX-1 for 0 to 132 feet.

133

Sets the Equalizer to DSX-1 for 133 to 265 feet.

266

Sets the Equalizer to DSX-1 for 266 to 398 feet.

399

Sets the Equalizer to DSX-1 for 399 to 532 feet.

533

Sets the Equalizer to DSX-1 for 533 to 655 feet.

Continued

Advertising