Vertical contact toaster, Sp - p 600, 400 sp - a – A.J. Antunes & Co VCT-2000 9210118 User Manual

Page 9: Operation (continued)

Advertising
background image

VERTICAL CONTACT TOASTER

9

P/N 1010832 Rev. E 02/13

TEMPERATURE CONTROL PANEL

To display the actual Platen temperature—providing it

is over 440°F (227°C)—press the

TEMP UP button.

To display the actual Auxiliary Air Heater temperature—

providing it is over 360°F (182°C)—press the

TEMP

DOWN button.
To switch the temperature display between Fahrenheit

(°F) and Celsius (°C), press and hold the

TEMP

SCALE button for 5 seconds.

PLATEN HEATER TEMPERATURE ADJUSTMENT

1. Turn the power on and wait for the Temperature

Display to finish the power up sequence

(Figure 4).

2. Press and hold both

TEMP UP and TEMP DOWN

buttons for over 1 second until the display flashes

the Platen setpoint temperature, then release.

3. Press the

TEMP UP button to raise the setpoint

temperature or press the

TEMP DOWN button to

lower the setpoint temperature.

NOTE: The Maximum Platen setpoint temperature

is 600°F (315°C).
NOTE: If no change in temperature is made within

5 seconds, the display reverts back to the previous

setpoint temperature.
4. Release the button when the desired setpoint

temperature is displayed.

AUXILIARY AIR HEATER TEMPERATURE ADJUSTMENT

1. Turn the power on and wait for the Temperature

Display to finish the power up sequence

(Figure 4).

2. Press and hold both

TEMP UP and TEMP

SCALE buttons for over 1 second until the

display flashes the setpoint temperature, then

release.

3. Press the

TEMP UP button to raise the setpoint

temperature or press the

TEMP DOWN button to

lower the setpoint temperature.

NOTE: The maximum Auxiliary Air Heater setpoint

temperature is 400°F (204°C).
4. Release the button when the desired setpoint

temperature is displayed.

NOTE: If no change in temperature is made within

5 seconds, the display reverts back to the previous

setpoint temperature.

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

SP - P

600

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

400

SP - A

Figure 4. Temperature Power Up Sequence

3. SP-A (Setpoint Auxiliary)

is displayed

1. SP-P (Setpoint Platen)

is displayed

“Heat On” LED will blink on/off during warm-up and when

either platen or auxiliary air heaters are calling for heat.

2. Current Platen setpoint

temperature setting is shown

4. Current Auxiliary Air setpoint

temperature is shown

5. “LO” is displayed until

platen temperature rises

above 550°F (288°C)

6. “USE” is displayed when

Platen setpoint temperature*

is reached

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

LO

USE

* Platen setpoint temperature must be between

460°F (238°C) and 600°F (315°).

OPERATION (continued)